Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

EN 50264 Medium Wall Power & C Location:Home> > English > Product Center > Rolling Stock Cables > EN 50264 Medium Wall Power & C >

FIREROL FRL-MW-1SU / FRL-MW-3SU 0.6/1 or 1.8/3 kV - single core

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-01-30 11:00   Browse times:second

EN 50264 Medium Wall Power & Control Cable

FIREROL FRL-MW-1SU/FRL-MW-3SU
0.6/1 or 1.8/3 kV - single core

EN 50264 FIREROL FRL-MW-1SU/FRL-MW-3SU

                                                    A. Conductor                    B. Insulation

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control,l auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5

Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)

Electrical & Mechanical Properties

Nominal Voltage 0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature +90 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-MW-1SU 0.6/1 kV

NOMINALCROSS-SECTIONAL AREA (a) CONDUCTOR DIAMETER (a) MIN. MEAN THICKNESS OF INSULATION OVERALL DIAMETER MIN.(mm) OVERALL DIAMETER MAX.(mm) WEIGHT CONDUCTOR RESISTANCE AT +20°C INSULATION RESISTANCE AT +20°C INSULATION RESISTANCE AT +90°C
max min min
mm2 mm mm mm mm Kg/km Ω/km MΩ·km MΩ·km
1.0 1.25 0.6 2.4 2.8 10 20 11.4 0.114
1.5 1.5 0.7 2.8 3.3 20 13.7 11.0 0.110
2.5 1.95 0.7 3.2 3.8 30 8.21 9.1 0.091
4 2.5 0.7 3.8 4.4 50 5.09 7.5 0.075
6 3.0 0.7 4.2 5.0 60 3.39 6.5 0.065
10 3.9 0.7 5.1 5.9 110 1.95 5.2 0.052
16 5.0 0.7 6.1 7.2 160 1.24 4.2 0.042
25 6.4 0.9 7.8 9.1 240 0.795 4.1 0.041
35 7.7 0.9 9.0 10.6 330 0.565 3.5 0.035
50 9.2 1.0 10.6 12.4 460 0.393 3.3 0.033
70 11.0 1.1 12.5 14.6 660 0.277 3.0 0.030
95 12.5 1.1 13.9 16.3 860 0.210 2.7 0.027
120 14.2 1.2 15.7 18.4 1080 0.164 2.7 0.027
150 15.8 1.4 17.6 20.6 1370 0.132 2.7 0.027
185 17.5 1.6 19.6 22.9 1690 0.108 2.6 0.026
240 20.1 1.7 22.2 26.0 2230 0.0817 2.6 0.026
300 22.5 1.8 24.6 28.8 2780 0.0654 2.4 0.024
400 25.8 2.0 28.1 32.9 3740 0.0495 2.4 0.024

FRL-MW-3SU 1.8/3 kV

NOMINALCROSS-SECTIONAL AREA

 

(a)
CONDUCTOR DIAMETER (a) MIN. MEAN THICKNESS OF INSULATION OVERALL DIAMETER MIN.(mm) OVERALL DIAMETER MAX.(mm) WEIGHT CONDUCTOR RESISTANCE AT +20°C INSULATION RESISTANCE AT +20°C INSULATION RESISTANCE AT +90°C
max min min
mm2 mm mm mm mm Kg/km Ω/km MΩ·km MΩ·km
1.5 1.5 2.0 5.3 6.2 50 13.7 21.0 0.210
2.5 1.95 2.0 5.7 6.7 60 8.21 18.0 0.180
4 2.5 2.0 6.2 7.3 80 5.09 15.5 0.155
6 3.0 2.0 6.7 7.8 100 3.39 13.7 0.137
10 3.9 2.0 7.5 8.8 150 1.95 11.5 0.115
16 5.0 2.0 8.6 10.0 220 1.24 9.5 0.095
25 6.4 2.0 9.9 11.6 290 0.795 7.9 0.079
35 7.7 2.0 11.1 13.0 390 0.565 6.8 0.068
50 9.2 2.0 12.5 14.6 530 0.393 5.9 0.059
70 11.0 2.0 14.2 16.6 720 0.277 5.0 0.050
95 12.5 2.2 16.0 18.7 940 0.210 4.5 0.045
120 14.2 2.2 17.6 20.6 1160 0.164 4.0 0.040
150 15.8 2.2 19.1 22.3 1440 0.132 3.7 0.037
185 17.5 2.4 20.9 24.4 1760 0.108 3.4 0.034
240 20.1 2.4 23.7 27.5 2350 0.0817 3.0 0.030
300 22.5 2.4 25.6 30.1 2820 0.0654 2.7 0.027
400 25.8 2.6 29.2 34.2 3730 0.0495 2.4 0.024